Space Needs Assessment
The Russell Memorial Library is a valued community resource that continues to demonstrate its importance to the Acushnet community through the resources, services, programs and staff it provides. However, the library is bursting at the seams and is need of additional space to accommodate both existing and new programs. The primary challenges for the library are:
- A lack of space to maintain quality in the management of the collection, materials and equipment and to accommodate users.
- A lack of consistent safety, accessibility and environmental quality throughout the building.
Generally, staff knowledge of community needs and interests and their professional training serve as the main criteria in appraising the collection for purchasing, replacing, or weeding.” In recent years, “available space” has become an unfortunate additional factor. Because the shelves are at capacity, the library needs to approach weeding as “one book in, one book out”. Even at full capacity, the current library facility is not able to meet the basic needs of the community.
COMPARISON OF RUSSELL MEMORIAL LIBRARY TO
WISCONSIN PUBLIC LIBRARY STANDARDS, 4th EDITION
All of today’s figures are based upon a population of 10,368 in 2008
and a projected population of 14,421 in 2030
|
Actual for Today |
Recommended for Today |
Recommended for 2030 |
Building Program for 2030 |
Print Volumes Held |
23,892 |
44,582 |
62,350 |
50,400 |
Periodicals Received |
87 |
119 |
164 |
125 |
Audio Recordings Held |
633 |
2,280 |
3,173 |
875 |
Video Recordings Held |
1,715 |
2,488 |
3,461 |
3,775 |
Reader/Computer Seats |
8 |
70 |
98 |
74 |
Given the size of the current building, it is impossible for the facility to remotely approach the Basic Level collection level. And perhaps the best way to illustrate space use is to show the current (substandard) collection and staff in its existing space, contrasted by the space it should have. The following table illustrates the minimum space that would be necessary to house these services adequately, even with no increase in collections or seating.
THE PHYSICAL PLANT IN 2010: HOW IS IT BEING USED?
AREA |
PRESENT FACILITY |
SQUARE FEET AS MEASURED |
EXPECTED BY STANDARD FORMULA |
Collections |
26,279 |
1,650 |
2,400 |
Seating |
4 |
100 |
180 |
Public Computers |
4 |
90 |
120 |
Circulation Services |
|
100 |
200 |
Staff Space/Storage |
|
450 |
950 |
Meeting Room |
Occupancy – 42 people |
500 |
520 |
SUBTOTAL |
|
2,890 |
4,370 |
25% unassigned |
|
725 |
1,100 |
Grand total required for holdings & facility |
Approx. 3,600 |
5,470 |
|
DEFICIENCY IN 2010 |
1,870 |
||
The library is clearly undersized to do the job it is doing today. The collection of 26,279 items, 4 seats for the public, 4 public access computers and a meeting room for 50 would be need a facility of roughly 5,470 square feet to be housed adequately. Since the present building is only 3,600 square feet, the space deficiency for the services being offered today is roughly 1,870 square feet. In order to create an accessible layout for current holdings and workspace, with no increase in seating, or a single additional book or computer workstation, we would need roughly 5,470 square feet.
summary of facility space requirements – future needs
The following information provides an estimate of the components and square footage requirements for a library facility based on an estimated population of 14,500 (20 year projection).
Area |
Sq Ft |
Materials |
Staff Computers |
Public Computers |
Patron Seats |
Browsing/New Materials |
320 |
500 |
1 |
6 |
|
Audiovisual Materials |
450 |
4775 |
|||
Magazine/Newspaper Area |
415 |
125 titles |
6 |
||
Reference Area |
375 |
1175 |
1 |
4 |
|
Information Technology |
525 |
- |
10 |
||
Adult Non-Fiction |
1430 |
12375 |
6 |
||
Adult Fiction |
1250 |
12050 |
2 |
||
Quiet Study Rooms |
120 |
4 |
|||
Adult Totals |
4885 |
30875 |
12 |
28 |
|
|
|
|
|
|
|
Young Adult Area |
930 |
3850 |
5 |
12 |
|
Children's Area |
2000 |
16175 |
3 |
14 |
|
Youth Totals |
2930 |
20025 |
8 |
26 |
|
|
|
|
|
|
|
Public Service Desk |
375 |
250 |
3 |
||
Director's Office |
125 |
75 |
1 |
||
Staff Room |
150 |
- |
|||
Storage |
350 |
- |
|||
Friends Area |
100 |
- |
|||
Staff Work Area |
650 |
500 |
3 |
||
Children's Office/Storage |
100 |
75 |
1 |
||
Administration Totals |
1850 |
900 |
8 |
||
|
|
|
|
|
|
Children's Program Room |
475 |
||||
Conference Room |
350 |
||||
Community Program Room |
1175 |
||||
Community Program/Meeting Space Totals |
2000 |
||||
|
|
|
|
|
|
Subtotals |
11665 |
||||
Non-Assignable Square Footage (25%) |
2916 |
||||
Estimated Grand Total |
14581 |